SLC-#/25-ADAPT 300X

UPS

Description

Salicru’s SLC ADAPT series consists of modular On-line double conversion uninterruptible power supply (UPS) solutions with DSP control and three-level IGBT inverter technology. 

Flexibility: It enables solutions to be configured from 25 kVA to 1500 kVA, thanks to the range of modules available (25, 30 and 50 kVA), different configurable systems (6, 8, 10 or 12 modules) and the parallel/redundant option of up to three 500 kVA systems. It also provides increased protection as needs grow - pay as you grow - thereby improving total cost of ownership (TCO).

Availability: Its hot-swap modules can be added or replaced during operation, thereby improving mean time to repair (MTTR) and reducing maintenance costs. In addition, the system’s remote management, which can be integrated into any platform, also facilitates operation. And the extensive back-up options available, along with intelligent battery charging, ensure continuous operation of the protected critical loads.

Reliability: Its DSP control, based on three-level PWM technology, improves response effectiveness and, along with shared load redundancy, significantly extends the mean time between failures (MTBF).

Technical Specifications

TECHNOLOGY - On-line double conversion, three-level PWM, DSP control


PHYSICAL - No. Modules (#) - 1 to 12


INPUT

Voltage - 3 x 380 / 400 / 415 V (3F + N)

Voltage range - -43% / +20% (1)

Rated frequency - 50 / 60 Hz

Frequency range - 40 - 70 Hz

Total harmonic distortion (THDi) - ≤3%

Power factor - >0.99


OUTPUT

Power factor - 1

Voltage - 3 x 380 / 400 / 415 V (3F + N)

Dynamic accuracy - ±1.5%

Static accuracy - ±1%

Power (VA/W) - 300000 / 300000

Maximum power (VA/W)  - 300000 / 300000

Frequency - 50 / 60 Hz

Module performance (On-line) - >96%

Performance in Smart Eco-mode - 99%

Admissible overloads - <110% for 1 hour / <125% for 10 min / <150% for 1 min / >150% for 200 ms


MANUAL BYPASS

Type - Uninterrupted


STATIC BYPASS

Type - Static thyristor

Three-phase voltage (V) - 3 x 380 / 400 / 415 (3P + N)

Admissible overloads - <110% permanent / <150% for 1 min


BATTERY

Battery type - Pb-Ca, VRLA, lead acid, gel, Ni-Cd, Li-Ion

Charging voltage regulation - Batt-watch

Charger maximum power (W) - 20% of total system power


COMMUNICATION

Display - 7” touchscreen, LEDs and keypad

Ports - RS-232, RS-485 and relays

Intelligent slot - 1 x Nimbus SNMP


GENERAL

Operating temperature - 0º C ÷ +55º C(2)

Relative humidity - Up to 95%, non-condensing

Maxium operating altitude - 2,400 masl(3)

Acoustic noise at 1 metre - <45 dB(A)


SYSTEMS

Maximum no. modules per system - 12

Maximum no. modules systems - 3


STANDARDS

Safety - EN-IEC 62040-1

Electromagnetic compatibility (EMC) - EN-IEC 62040-2

Operation - VFI-SS-111 (EN-IEC 62040-3)

Quality and environmental management - ISO 9001 & ISO 14001


DIMENSIONS

Depth (mm) - 960

Width (mm) - 650

Height (mm) - 2000


WEIGHT

Weight (kg) - 230


(1) Depending on load percentage.

(2) Power derating for higher altitudes up to +40ºC.

(3) Power degradation for temperature altitudes, up to a maximum of 5,000 masl.

Related Products