Salicru’s SLC ADAPT series consists of modular On-line double conversion uninterruptible power supply (UPS) solutions with DSP control and three-level IGBT inverter technology.
Flexibility: It enables solutions to be configured from 25 kVA to 1500 kVA, thanks to the range of modules available (25, 30 and 50 kVA), different configurable systems (6, 8, 10 or 12 modules) and the parallel/redundant option of up to three 500 kVA systems. It also provides increased protection as needs grow - pay as you grow - thereby improving total cost of ownership (TCO).
Availability: Its hot-swap modules can be added or replaced during operation, thereby improving mean time to repair (MTTR) and reducing maintenance costs. In addition, the system’s remote management, which can be integrated into any platform, also facilitates operation. And the extensive back-up options available, along with intelligent battery charging, ensure continuous operation of the protected critical loads.
Reliability: Its DSP control, based on three-level PWM technology, improves response effectiveness and, along with shared load redundancy, significantly extends the mean time between failures (MTBF).
Technical Specifications
TECHNOLOGY - On-line double conversion, three-level PWM, DSP control
PHYSICAL - No. Modules (#) - 1 to 12
INPUT
Voltage - 3 x 380 / 400 / 415 V (3F + N)
Voltage range - -43% / +20% (1)
Rated frequency - 50 / 60 Hz
Frequency range - 40 - 70 Hz
Total harmonic distortion (THDi) - ≤3%
Power factor - >0.99
OUTPUT
Power factor - 1
Voltage - 3 x 380 / 400 / 415 V (3F + N)
Dynamic accuracy - ±1.5%
Static accuracy - ±1%
Power (VA/W) - 300000 / 300000
Maximum power (VA/W) - 300000 / 300000
Frequency - 50 / 60 Hz
Module performance (On-line) - >96%
Performance in Smart Eco-mode - 99%
Admissible overloads - <110% for 1 hour / <125% for 10 min / <150% for 1 min / >150% for 200 ms
MANUAL BYPASS
Type - Uninterrupted
STATIC BYPASS
Type - Static thyristor
Three-phase voltage (V) - 3 x 380 / 400 / 415 (3P + N)
Admissible overloads - <110% permanent / <150% for 1 min
BATTERY
Battery type - Pb-Ca, VRLA, lead acid, gel, Ni-Cd, Li-Ion
Charging voltage regulation - Batt-watch
Charger maximum power (W) - 20% of total system power
COMMUNICATION
Display - 7” touchscreen, LEDs and keypad
Ports - RS-232, RS-485 and relays
Intelligent slot - 1 x Nimbus SNMP
GENERAL
Operating temperature - 0º C ÷ +55º C(2)
Relative humidity - Up to 95%, non-condensing
Maxium operating altitude - 2,400 masl(3)
Acoustic noise at 1 metre - <45 dB(A)
SYSTEMS
Maximum no. modules per system - 12
Maximum no. modules systems - 3
STANDARDS
Safety - EN-IEC 62040-1
Electromagnetic compatibility (EMC) - EN-IEC 62040-2
Operation - VFI-SS-111 (EN-IEC 62040-3)
Quality and environmental management - ISO 9001 & ISO 14001
DIMENSIONS
Depth (mm) - 960
Width (mm) - 650
Height (mm) - 2000
WEIGHT
Weight (kg) - 230
(1) Depending on load percentage.
(2) Power derating for higher altitudes up to +40ºC.
(3) Power degradation for temperature altitudes, up to a maximum of 5,000 masl.