Description
Salicru's SLC TWIN PRO2 series is a UPS range in a tower format equipped with on-line double-conversion technology and the latest features to make it an advanced protection system for sensitive and critical loads. High output power factor (PF=0.9) to ensure availability to all types of loads.
Full control through status information via LCD display and keypad. And extensive monitoring and communication options via the built-in USB HID interface, an intelligent slot for SNMP cards or relays and a wide range of software packages available – free monitoring version downloadable for Windows, Linux, Unix or Mac and packages available for multi servers or virtualised systems. For facilities that require more back-up time, there is a possibility of backup extensions using UPSs with extra charger and additional battery modules. Also notable is the possibility of Eco-mode operation to improve the efficiency of the device, EPO (emergency power off) functions, operation as a frequency converter and built-in battery test.
Salicru's SLC TWIN PRO2 range is available in power ratings of 700, 1000, 1500, 2000 and 3000 VA.
Technical Specifications
TECHNOLOGY - On-line double-conversion
FORMAT - Tower
INPUT
Rated voltage - 220 / 230 / 240 V
Voltage range 100% load - 176 ÷ 300 V
Voltage range 40% load - 100 ÷ 300 V
Rated frequency - 50 / 60 Hz
Frequency range - ±10%
Total harmonic distortion (THDi) - <4%
Power factor - &ge0.125
Auto~detection of frequency - Yes
Protection - Resettable circuit breaker
OUTPUT
Power factor - 0.9
Waveform - Pure sine wave
Rated voltage - 220 / 230 / 240 V
Voltage accuracy - ±1%
Power (VA/W) - 1000 / 900
Total harmonic distortion (THDv) - <2%
Synchronised frequency - ±10%
Free running frequency - ±0.05 Hz
Frequency - 50 / 60 Hz
Frequency accuracy (battery mode) - ±0.05Hz
Compatibility with APFC loads - Yes
On-line performance - >89%÷92%
Eco-mode performance - >97,2%
Admissible overloads in battery mode - 105% constant / 130% for 10 s / 150% for 1 s
Admissible overloads in bypass mode - 130% constant / 180% for 60 s
Admissible overloads in-line mode - 105% constant / 130% for 60 s / 150% for 10 s / >150% for 300ms
Socket type - IEC
No. Of sockets - 4xC13
BYPASS
Frequency range - ±5Hz
Transfer time - 4 ms
BATTERY
Battery type - Pb-Ca sealed, AGM, maintenance-free
Charge type - I/U (constant current/constant voltage)
Recharge time - 4 hours to 90%
Battery test - Manual and/or automatic programmable
COMMUNICATION
Ports - USB HID
Intelligent slot - Slot for SNMP/relays
Monitoring software - For Windows, Linux and Mac
INDICATIONS
Type - LCD + keypad
OTHER FUNCTIONS
Cold start (start-up from batteries) - Yes
Automatic restart - Yes
Emergency stop (EPO) - Yes
OPERATING MODES
On-line double-conversion - Yes
Eco-mode - Yes
Frequency converter (CVCF) - Yes (1)
GENERAL
Operating temperature - 0º C ÷ 40º C
Relative humidity - Up to 95%, non-condensing
Maxium operating altitude - 2,400 masl (power degradation up to 5,000 m)
Acoustic noise at 1 metre - ≤49 dB (100% load) / ≤41 dB (60% load)
STANDARDS
Safety - EN-IEC 62040-1
Electromagnetic compatibility (EMC) - EN 62040-2
Operation - VFI (EN-62040-3)
Quality and environmental management - ISO 9001 & ISO 14001
DIMENSIONS
Depth (mm) - 346
Width (mm) - 102
Height (mm) - 228
WEIGHT
Weight (kg) - 4,9
(1) up to 60% of the load