top of page

SLC-1000-TWIN PRO2 B1 IEC

Buy Now

Email: sale@theupsteam.co.uk
Web Form

Enquire About The

Email: sale@theupsteam.co.uk
Web Form

SLC-1000-TWIN PRO2 B1 IEC

UPS

Description

Salicru's SLC TWIN PRO2 series is a UPS range in a tower format equipped with on-line double-conversion technology and the latest features to make it an advanced protection system for sensitive and critical loads. High output power factor (PF=0.9) to ensure availability to all types of loads.

Full control through status information via LCD display and keypad. And extensive monitoring and communication options via the built-in USB HID interface, an intelligent slot for SNMP cards or relays and a wide range of software packages available – free monitoring version downloadable for Windows, Linux, Unix or Mac and packages available for multi servers or virtualised systems. For facilities that require more back-up time, there is a possibility of backup extensions using UPSs with extra charger and additional battery modules. Also notable is the possibility of Eco-mode operation to improve the efficiency of the device, EPO (emergency power off) functions, operation as a frequency converter and built-in battery test.

Salicru's SLC TWIN PRO2 range is available in power ratings of 700, 1000, 1500, 2000 and 3000 VA.

Technical Specifications

TECHNOLOGY - On-line double-conversion


FORMAT - Tower


INPUT

Rated voltage - 220 / 230 / 240 V

Voltage range 100% load - 176 ÷ 300 V

Voltage range 40% load - 100 ÷ 300 V

Rated frequency - 50 / 60 Hz

Frequency range - ±10%

Total harmonic distortion (THDi) - <4%

Power factor - &ge0.125

Auto~detection of frequency - Yes

Protection - Resettable circuit breaker


OUTPUT

Power factor - 0.9

Waveform - Pure sine wave

Rated voltage - 220 / 230 / 240 V

Voltage accuracy - ±1%

Power (VA/W) - 1000 / 900

Total harmonic distortion (THDv) - <2%

Synchronised frequency - ±10%

Free running frequency - ±0.05 Hz

Frequency - 50 / 60 Hz

Frequency accuracy (battery mode) - ±0.05Hz

Compatibility with APFC loads - Yes

On-line performance - >89%÷92%

Eco-mode performance - >97,2%

Admissible overloads in battery mode - 105% constant / 130% for 10 s / 150% for 1 s

Admissible overloads in bypass mode - 130% constant / 180% for 60 s

Admissible overloads in-line mode - 105% constant / 130% for 60 s / 150% for 10 s / >150% for 300ms

Socket type - IEC

No. Of sockets - 4xC13


BYPASS

Frequency range - ±5Hz

Transfer time - 4 ms


BATTERY

Battery type - Pb-Ca sealed, AGM, maintenance-free

Charge type - I/U (constant current/constant voltage)

Recharge time - 4 hours to 90%

Battery test - Manual and/or automatic programmable


COMMUNICATION

Ports - USB HID

Intelligent slot - Slot for SNMP/relays

Monitoring software - For Windows, Linux and Mac


INDICATIONS

Type - LCD + keypad


OTHER FUNCTIONS

Cold start (start-up from batteries) - Yes

Automatic restart - Yes

Emergency stop (EPO) - Yes


OPERATING MODES

On-line double-conversion - Yes

Eco-mode - Yes

Frequency converter (CVCF) - Yes (1)


GENERAL

Operating temperature - 0º C ÷ 40º C

Relative humidity - Up to 95%, non-condensing

Maxium operating altitude - 2,400 masl (power degradation up to 5,000 m)

Acoustic noise at 1 metre - ≤49 dB (100% load) / ≤41 dB (60% load)


STANDARDS

Safety - EN-IEC 62040-1

Electromagnetic compatibility (EMC) - EN 62040-2

Operation - VFI (EN-62040-3)

Quality and environmental management - ISO 9001 & ISO 14001


DIMENSIONS

Depth (mm) - 346

Width (mm) - 102

Height (mm) - 228


WEIGHT

Weight (kg) - 4,9

(1) up to 60% of the load

Related Products

bottom of page