Description
Salicru's SLC TWIN RT2 UPS range is a highly advanced continuity solution for the electrical protection of critical systems. It combines the most reliable double-conversion technology (AC/DC-DC/AC) on the market and boasts a unity output power factor (VA=W) to enable it to power systems with high energy requirements, while offering high operating efficiency.
The range of power ratings from 700 VA(W) to 3,000 VA(W), it comes in a 2U, convertible to tower format, with a swivel mount LCD display, according to the needs of the facility. Also available are solutions with an extra charger and additional battery modules for applications that require greater backup.
In terms of communications, it features an RS-232/USB interface compatible with HID protocol and a smart slot that can optionally hold an SNMP card, MODBUS or potential free contacts; also available are software packages for local or virtual monitoring and management of protected devices. Other outstanding features include: 50/60 or 60/50 Hz frequency converter, emergency stop (EPO), and programmable outputs for critical/non-critical loads.
Technical Specifications
TECHNOLOGY - On-line double-conversion
FORMAT - Convertible tower/rack
INPUT
Rated voltage - 200 / 208 / 220 / 230 / 240 V (1)
Voltage range 60% load - 110 ÷ 300 V up to 60% load
Rated frequency - 50 / 60 Hz (auto-detection)
Frequency range - ±10 Hz
Total harmonic distortion (THDi) - ≤5%
Auto~detection of frequency - Yes
OUTPUT
Power factor - 1
Waveform - Pure sine wave
Rated voltage - 200 / 208 / 220 / 230 / 240 V (1)
Voltage accuracy - ±1%
Power (VA/W) - 700 / 700
Total harmonic distortion (THDv) - < 2% linear load / < 4% non-linear load
Synchronised frequency - ±3 Hz
Free running frequency - ±0.1 Hz
Frequency - 50 / 60 Hz
On-line performance - ≥89 ÷ 91%
Eco-mode performance - ≥95 ÷ 97%
Admissible overloads - < 130% for 5 min / < 140% for 30 s / <150 % for 1.5 s / 150 % for 100 ms
Socket type - IEC
No. Of sockets - 8
Programmable sockets - Yes, for critical / non-critical loads (4/4)
BYPASS
Rated voltage - 200 / 208 / 220 / 230 / 240 V (1)
Frequency range - 50/60Hz ±10 Hz
BATTERY
Battery type - Pb-Ca sealed, AGM, maintenance-free
Charge type - I/U (constant current/constant voltage)
Recharge time - 3 hours to 95%
CHARGER
Temperature voltage compensation - Yes
COMMUNICATION
Ports - USB-HID / RS-232
Intelligent slot - Slot for SNMP/potential-free contacts/ MODBUS
Monitoring software - For Windows, Linux and Mac
INDICATIONS
Type - LCD + keypad
OTHER FUNCTIONS
Cold start (start-up from batteries) - Yes
Emergency stop (EPO) - Yes
ADSL/fax/modem transient protector - Yes
OPERATING MODES
Frequency converter (CVCF) - Yes (2)
GENERAL
Operating temperature - 0º C ÷ 55º C(3)
Relative humidity - Up to 95%, non-condensing
Maxium operating altitude - 2,400 masl (power degradation up to 5,000 m)
Acoustic noise at 1 metre - < 50 dB
STANDARDS
Safety - EN-IEC 62040-1
Electromagnetic compatibility (EMC) - EN 62040-2(C2)
Operation - EN 62040-3
Quality and environmental management - ISO 9001 & ISO 14001
DIMENSIONS
Depth (mm) - 405
Width (mm) - 438
Height (mm) - 88
WEIGHT
Weight (kg) - 7,8
(1) 80% power reduction for 200 or 208 V devices
(2) 78% power reduction
(3) 4% power derating per each degree over 40ºC